Age | Commit message (Collapse) | Author |
|
|
|
actually compile)
|
|
|
|
Fix the config bugs revealed by the updated config system.
-Erik
|
|
|
|
|
|
|
|
|
|
If we read the contents of compressed files within the ar archive,
e.g. control.tar.gz, then file position gets all out of whack, so
it has to be reset before reading thenext header.
|
|
|
|
|
|
When using "losetup" the device is always setup as Read-Only.
(I have only tested with the -o flag, but looking at the code the
problem seems general)
The problem is the "opt" variable in "losetup.c" that is reused in
the "set_loop()" call. Clear it before the call and everything is OK;
opt = 0; /* <-------- added line */
if (delete)
return del_loop (argv[optind]) ? EXIT_SUCCESS : EXIT_FAILURE;
else
return set_loop (argv[optind], argv[optind + 1], offset, &opt)
? EXIT_FAILURE : EXIT_SUCCESS;
}
Best Regards,
Lars Ekman
|
|
|
|
|
|
The recent changes in ifupdown where all calls to 'ip link set' and
'ip addr set' are swapped give some problems with v4tunnels.
For plain ipv4 and ipv6 interfaces it works correct, other methods
not tried. The patch below change the behaviour back for v4tunnels
only.
Without the patch the following errors are shown:
RTNETLINK answers: Network is down
RTNETLINK answers: No route to host
and the tunnel is not fully brought up
With this patch all works as expected.
|
|
This moment have algoritmicaly problem, not overflow:
strcat(wrapped, wrapped) - may be looped.
Hand patch:
- else if (strstr(strcat(wrapped, wrapped), newmono))
+ else {
+ safe_strncpy(wrapped + lenwrap, wrapped, lenwrap + 1);
+ if (strstr(wrapped, newmono))
+}
--w
vodz
|
|
|
|
The login process should always timeout if user don't login sucessfully within
reasonable time. Otherwise we're sensetive to a DOS attack by simply doing a
bunch of simultaneous telnet connections (deploys all availible TTY's).
This patch make login.c terminate the connection after "TIMEOUT" seconds.
|
|
If BusyBox was compiled with -DCONFIG_FEATURE_CLEAN_UP dmesg command
segfaults if invoked with the "-n" option. (Due to a free() of an
uninitialized pointer).
|
|
|
|
|
|
|
|
this patch fixes run_parts when it's called by ifupdown. 1) argv has to be a
NULL terminated char* array, not just a string. 2) run_parts now explicitly
sets the environment. this environment is populated from the
/etc/network/interfaces config file and is needed by the scripts in
/etc/network/if-pre-up.d/. when run-parts is called from the command line the
environment is taken from the current process.
Vladimir Oleynik then wrote:
You can simplify this if use:
+ bb_xasprintf(&buf[0], "/etc/network/if-%s.d", opt);
+ buf[1] = NULL;
+
+ run_parts(&buf, 2, environ);
+ free(buf[0]);
--w
vodz
|
|
Last patch have synced form Manuel Nova III xxreadtoken() function,
corrected (C) form dash debian/copyright, removed my small mistake
with IFS_BROKEN (thanks by Herbert), and synced cmdedit.c from
current CVS (removed libc5 support, your email correction, my (C) year
corertion).
|
|
>I'm sure that no user process use old root now, but when run "umount
>/old_root", it says:
> umount: /old_root: Device or resource busy
>
>I have tried to remount /proc within the new root *after* chroot, but
>get the same result.
>
>
I found the problem, I said that no user process use old root when run
my scripts, but
I'm wrong, actually there is a '3' fd open the file
"/old_root/dev/console". By adding
debug message in init/init.c, I found the problem: when init restart(in
exec_signal()),
before open the new terminal device, there is still a file opened(I
don't know which file it is), so the
terminal device(stdin) get fd '1', and the first dup(0)(stdout) return
'2', the second(stderr) return '3'.
I attach a simple patch to solve this problem.
|
|
|
|
|
|
|
|
version:
ftp://ftp.simtreas.ru/pub/my/bb/new
News:
- code is smalest!
- support ${var...} expr
- used new very strongly steal controlling terminal
|
|
|
|
|
|
|
|
Denis,
># ./busybox env - echo zzz
>zzz
># ./busybox echo -n zzz
>zzz
># ./busybox env - echo -n zzz
>env: invalid option -- n
>
> obviously, env tried to understand -n as env's option
> instead of blindly passing it to echo...
>
>BusyBox v1.00-pre1 (2003.07.16-07:53+0000) multi-call binary
>
>Usage: env [-iu] [-] [name=value]... [command]
Ah, you found very old problem.
Last patch also have:
- multiple "-u unsetenv" support
- GNU long option support
- save errno after exec failed before bb_perror_msg()
--w
vodz
|
|
Hi.
Last patch have new libbb function
vfork_rexec() for can use daemon() to uClinux system.
This patched daemons: syslog, klogd, inetd, crond.
This not tested! I havn`t this systems.
Also. Previous patch for feature request MD5 crypt password for
httpd don`t sended to this mailist on 07/15/03
(mailist have Pytom module problem?).
The previous patch included, and have testing.
--w
vodz
|
|
|
|
I've found a possible bug in libbb/interface.c, in function
if_readlist_proc(). This function calls get_name(), and passes
as an argument 'name', a buffer of 16 bytes (IFNAMSIZ). The
function get_name(), however, may use more than 16 bytes,
when it is searching for aliases. Even if you don't have an
alias interface, you can run into trouble if the interface
has received more than 99999999 bytes, in which case the
space between the interface name and the rx stats
disappears, as in the /proc/net/dev example below:
wan0.200:264573315 462080 ...
In this case get_name() correctly identifies the interface name
as "wan0.200", but to do that it uses 18 bytes of the 'name'
buffer, which could lead to an unpredictable error.
A simple solution would be to increase the size of the buffer:
|
|
|
|
|
|
Cleanup run_parts a bit and add long opts
|
|
|
|
since it can also be used with other syslog daemons
-Erik
|
|
The client gives up way too soon because timeout is set to 0 ...
There's a solution for that problem.
|
|
|
|
which were not properly using the bb_path_*_file strings.
|
|
to abuse.
-Erik
|
|
reparented to init...
|
|
since fdisk will work just fine on smaller disks w/o it.
|
|
timezone setting is used for the new date.
|
|
|
|
last_patch97 from vodz
|